Solutions OMPECO Technologies Services Project Intelligence Industries About Contact Evaluate a Project
OMPECO Converter® Platform

Onsite Waste Transformation for Demanding Operating Environments.

The OMPECO Converter® is a patented waste transformation platform that uses friction-generated moist heat to sterilize, dehydrate, and reduce waste volume at the point of generation. No combustion, no chemicals, no microwaves, no pressure vessels. Designed for healthcare, municipal, industrial, and naval applications where reliable, compliant onsite waste treatment is mission-critical.

How It Works

From Waste Input to Sterile, Reduced Output

The Converter® platform transforms waste through a continuous mechanical process that generates the heat needed for sterilization and dehydration without external thermal sources.

Seven Steps. 30 Minutes Only.

1

Waste Loading

Waste loaded inside chamber by hand in plastic bags, lid closed

→
2

Crushing

Rotor starts, accelerates gradually, material finely ground, temperature rises to ~100°C

→
3

Evaporation

Friction heat causes evaporation of waste moisture, temperature constant at ~100°C

→
4

Superheating

Once moisture eliminated, temperature increases to 151°C

→
5

Sterilization

Temperature held at 151°C for 3 minutes under moist heat with controlled water dosage

→
6

Cooling Down

Waste sprinkled with water to ~100°C, vacuum pump lowers to ~60°C adiabatically

→
7

Unloading

Treated material unloaded by centrifugal force through servo-operated valve

No Combustion
No Chemicals
No Microwaves
No Pressure Vessels
ISO 9001
NATO AH649
RINA
M.O.G.C. 231
APHIS
APHA
Converter® H Series

Healthcare & Medical Waste

The H Series is designed for hospitals, clinics, laboratories, and medical waste service providers who require reliable, compliant onsite treatment of infectious and biohazardous waste streams. Process waste at the point of generation to reduce storage requirements, eliminate transport risks, and improve facility workflows.

Applications

  • Infectious and biohazardous waste
  • Sharps containers and medical devices
  • Laboratory waste and cultures
  • Pathological waste
Evaluate an H Series Project
Key Benefits
Point-of-generation treatment
Reduced storage & transport
Up to 80% volume reduction
Up to 50% weight reduction*
Validated sterilization
Improved facility workflows
Output storable up to 90 days
RDF potential: 3.5–4.5 MWh/t
Waste Category Healthcare / Medical
Sterilization Level STAATT Level IV
Volume Reduction Up to 80%
Output Classification Non-hazardous solid waste
Weight Reduction Up to 50%
Output Storage Up to 90 days, no refrigeration
RDF Energy Potential 3.5–4.5 MWh/t

*Based on the moisture content of the input waste. Output is odorless and can be stored up to 90 days without refrigeration.

Municipal & Industrial

General, Organic & Industrial Waste Streams

The Converter® platform addresses a broad range of non-healthcare waste streams, from municipal solid waste and food waste to industrial by-products, sludge, and biomass. The processed output can potentially be classified as Refuse-Derived Fuel (RDF), creating additional value from waste streams that would otherwise require costly disposal.

Applications

  • Municipal solid waste (MSW)
  • Commercial and organic waste
  • Industrial process waste
  • Food waste and sludge
  • Biomass and agricultural residues
RDF Potential: Processed output may qualify as Refuse-Derived Fuel, subject to waste composition and local regulations.
Waste Stream Capabilities
Municipal Solid Waste Supported
Commercial Waste Supported
Organic / Food Waste Supported
Industrial By-Products Model-Dependent
Sludge & Biomass Model-Dependent
RDF Output Potential Yes
Converter® NV Series

Naval, Maritime & Remote Operations

The NV Series is purpose-engineered for constrained operating environments where space, weight, vibration, and operational continuity are critical factors. Designed for naval vessels, cruise ships, offshore platforms, remote camps, military installations, and mobile facilities where waste cannot be stored indefinitely or transported easily.

Designed For

  • Naval vessels and warships
  • Cruise ships and ferries
  • Offshore platforms and FPSOs
  • Remote camps and expeditionary bases
  • Military and defense installations
  • Mobile and containerized facilities
Evaluate an NV Series Project
Naval Specifications
Installation Compact footprint, below-deck
Vibration Rating Naval-grade certified
Power Integration Ship electrical systems
MARPOL Compliance Supported
Containerized Option Available
Eliminates waste storage at sea
Reduces port disposal costs
Continuous operation capable
Minimal crew training required
Technical Specifications

Converter® H Series — Full Product Range

Eight models ranging from compact 25-litre units for clinics and field operations to industrial 5,000-litre systems for large hospitals and centralized treatment facilities. All models share the same patented friction-heat sterilization process.

H5000
5,000 L chamber
Throughput
500–600 kg/h
Total Power
520 kW
Motor
500 kW
Current
600A (750A peak)
Consumption
0.4–0.6 kWh/kg
Weight
16,000 kg
Footprint
8000×2500 mm
Height
6,500 mm
Cabinet
1,200 kg
500–600 kg/h
H2000
2,000 L chamber
Throughput
250–350 kg/h
Total Power
360 kW
Motor
350 kW
Current
400A (480A peak)
Consumption
0.4–0.6 kWh/kg
Weight
14,000 kg
Footprint
6700×2500 mm
Height
6,500 mm
Cabinet
1,000 kg
250–350 kg/h
H1000
1,000 L chamber
Throughput
150–200 kg/h
Total Power
260 kW
Motor
250 kW
Current
300A (360A peak)
Consumption
0.4–0.6 kWh/kg
Weight
12,000 kg
Footprint
6700×2500 mm
Height
5,900 mm
Cabinet
800 kg
150–200 kg/h
H400
400 L chamber
Throughput
60–80 kg/h
Total Power
100 kW
Motor
85 kW
Current
120A (150A peak)
Consumption
0.4–0.6 kWh/kg
Weight
2,200 kg
Footprint
2300×1500 mm
Height
1,800 mm
Cabinet
450 kg
60–80 kg/h
H200
200 L chamber
Throughput
30–40 kg/h
Total Power
65 kW
Motor
60 kW
Current
95A (120A peak)
Consumption
0.4–0.6 kWh/kg
Weight
1,500 kg
Footprint
1950×1200 mm
Height
1,400 mm
Cabinet
450 kg
30–40 kg/h
H100
100 L chamber
Throughput
15–20 kg/h
Total Power
55 kW
Motor
50 kW
Current
70A (80A peak)
Consumption
0.4–0.6 kWh/kg
Weight
1,100 kg
Footprint
1500×1100 mm
Height
1,400 mm
Cabinet
450 kg
15–20 kg/h
H50
50 L chamber
Throughput
8–12 kg/h
Total Power
10 kW
Weight
250 kg
Footprint
700×700 mm
Height
1,100 mm
8–12 kg/h
H25
25 L chamber
Throughput
4–6 kg/h
Total Power
2.8 kW
Weight
110 kg
Footprint
700×600 mm
Height
900 mm
4–6 kg/h

All H Series models feature the same patented friction-heat sterilization process. Energy consumption across the range: 0.4–0.6 kWh/kg. Up to 80% volume reduction, up to 50% weight reduction.

Find the Right Model for Your Project
Planning Requirements

Site & Utility Considerations

Every installation is unique. The following factors are evaluated during the project development phase to ensure optimal system configuration and site readiness.

Space Requirements

Floor area, ceiling height, door access, structural loading capacity, and equipment clearance zones for maintenance access.

Electrical Supply

Voltage, amperage, phase configuration, and available capacity. Transformer or panel upgrades may be required depending on the model.

Water & Drainage

Water supply requirements for cooling and process needs, plus drainage capacity for condensate and process water discharge.

Ventilation & Exhaust

Air handling requirements including exhaust ductwork, filtration systems, and ambient temperature management for the operating environment.

Regulatory Environment

Local and national waste treatment regulations, permitting requirements, emissions standards, and compliance documentation needs.

Waste Logistics

Internal waste collection workflows, container handling, loading procedures, output storage, and disposal routing for processed material.

Lifecycle Support

Service & Maintenance

Every OMPECO installation is supported by Valtara's comprehensive service infrastructure, ensuring maximum uptime and optimal system performance throughout the equipment lifecycle.

Preventive Maintenance

Scheduled inspections, wear-part replacement, and condition monitoring programs.

Corrective Service

Rapid-response technical support, diagnostics, and repair services for unplanned events.

Genuine Spare Parts

Factory-certified components and consumables with managed inventory and rapid delivery.

Remote Diagnostics

Connected monitoring capabilities for proactive issue detection and performance optimization.

Frequently Asked Questions

Common Questions About the Technology

The Converter uses mechanical friction to generate moist heat for sterilization and dehydration. There is no combustion, no open flame, and no exhaust stack emissions associated with incineration. This means no air quality permits related to combustion, no ash residue, and significantly simplified regulatory compliance in most jurisdictions.

Depending on the model and configuration, the Converter can process infectious medical waste, biohazardous materials, sharps, laboratory waste, municipal solid waste, organic waste, food waste, industrial by-products, sludge, and biomass. The specific waste types suitable for each model depend on composition, moisture content, and local regulatory requirements.

The healthcare models achieve STAATT Level IV sterilization, which is the highest level of microbial inactivation recognized for alternative waste treatment technologies. This has been validated through independent third-party testing with biological indicators including B. stearothermophilus, B. subtilis, and mycobacterium species.

Volume reduction of up to 80% and weight reduction of up to 50% are achievable, depending on the moisture content of the input waste stream. High-moisture waste streams such as food waste and organic materials typically see greater weight reduction due to the dehydration process. The output is odorless and can be stored up to 90 days without refrigeration. Processed output may also qualify as Refuse-Derived Fuel (RDF) with an energy potential of 3.5–4.5 MWh/t.

The Converter is designed for operation by trained facility staff. Valtara provides comprehensive operator training and certification programs as part of every deployment. Day-to-day operation involves waste loading, cycle management, and output handling, and does not require engineering-level technical skills.

The Converter requires electrical power (specifications vary by model), a water supply for cooling purposes, and drainage for condensate discharge. No gas supply, steam supply, or specialized chemical inputs are required. Specific utility requirements are determined during the project development phase based on the selected model and site conditions.

The output is a dry, sterile, unrecognizable material that is typically classified as non-hazardous solid waste. It can be disposed of through standard municipal waste channels in most jurisdictions. For certain waste streams, the output may qualify as Refuse-Derived Fuel (RDF), creating potential value recovery opportunities. Output classification is subject to local regulations.

Suitability depends on multiple factors including the specific Converter model, waste stream composition and volume, local regulatory requirements, site conditions, and operating environment. We recommend starting with a project evaluation through our team or the Project Intelligence platform to determine whether the technology is appropriate for your application.

Product Suitability Disclaimer

The suitability of any OMPECO Converter® model for a specific application depends on multiple factors including the Converter model and configuration, waste stream composition and characteristics, applicable local and national regulations, specific operating conditions and environment, and site-specific infrastructure requirements. The information provided on this page is for general informational purposes. All product specifications, performance claims, and application suitability must be confirmed through a formal project evaluation with qualified Valtara and OMPECO representatives. Performance data may vary based on actual operating conditions.

Evaluate the Right OMPECO Solution for Your Facility

Tell us about your waste streams, operating environment, and project objectives. Our team will provide an initial assessment of which Converter model and configuration may be appropriate for your application.